EEx OG 9
Download...
|
|
Counts per turn:
|
1 - 5,000
|
|
EURO-Flange B10; shaft d= 11 mm
|
|
Max. output frequency:
|
120 (250) kHz
|
High HTL output current
|
|
Logic level:
|
HTL; TTL; TTL (R)
|
|
|
Permissible encoder temperature:
|
-20 °C bis +55 °C
|
|
|
Connection:
|
Terminal box
|
Explosion protection "II 2G Ex de IIC T6"
|
|
Weight:
|
approx. 3.5 kg
|
|
|
Shock resistance:
|
1,000 m/s² (6 ms)
|
|
|
Protection class:
|
IP 56
|
|
|
|
EEx HOG 161
Download...
|
|
Counts per turn:
|
250 - 2,500
|
|
Hollow shaft d= 30 to 70 mm
|
|
Max. output frequency:
|
120 kHz
|
|
|
Logic level:
|
HTL; TTL; TTL (R)
|
|
|
Permissible encoder temperature:
|
-20 °C to +65 °C (T5)
-20 °C to +70 °C (T6)
|
|
|
Connection:
|
Terminal box
|
Explosion protection "II 2G Ex de IIC T6 (IP 54)"
|
|
Weight:
|
approx. 8.8 kg d=40
approx. 6.2 kg d=70
|
Explosion protection "II 2G Ex de IIC T5 (IP 56)"
|
|
Shock resistance:
|
1,000 m/s² (6 ms)
|
|
|
Protection class:
|
IP 56 for T5
IP 54 for T6
|
|
|
|
EEx ME 12
Download...
|
|
Motor earthing unit to by-pass shaft currents
|
|
Hollow shaft d= 40 and d= 70mm
|
|
Max. speed:
|
8,500 rpm
|
|
|
Max. Current:
|
1 A short-term load: 12 A
|
|
|
Permissible unit temperature:
|
-20 °C to +50 °C
|
|
|
Connection:
|
Earthing screw
|
|
|
Weight:
|
approx. 3.5 kg
|
Explosion protection "II 2G Ex de IIC T5"
|
|
Shock resistance:
|
1,000 m/s² (6 ms)
|
|
|
Protection class:
|
IP 56
|
|
|
|
|
|
|
|
EEx GP 0,2 (TG 74 d)
Download...
|
|
"EEx de IIC T6"
|
|
|
EURO-Flange B10
|
|
Voltage:
|
20-150 mV/rpm
|
Shaft:
|
Ø 11 mm (Ø 14 mm)
|
|
Temperature coefficient:
|
±0.006 %/K
|
Max. speed:
|
8,000 -> 2,800 rpm
|
|
Superimposed ripple:
|
<= 0.6 %ss
|
Moment of inertia:
|
1.15 kgcm2
|
|
Time constant:
|
<= 150 µs
|
Weight:
|
approx. 3.8 kg
|
|
Power:
|
12W, n>= 3000 min-1
|
Protection class:
|
IP 54
|
|
|
|
|
|
|
|
|
|
Technical modifications reserved.
|